我們經(jīng)常會(huì )有患得患失的情況,對于廠(chǎng)房,倉庫來(lái)說(shuō),需要保護廠(chǎng)房,倉庫的產(chǎn)品和設備,現階段使用川消消防水炮是較為理想的消防防火、滅火產(chǎn)品,但是在水炮調試的情況下會(huì )出現各種常見(jiàn)的問(wèn)題。這種患得患失的情況下,該怎么做呢?
We often have a situation of worrying about gains and losses. For factories and warehouses, it is necessary to protect the product and equipment safety of the factories and warehouses. Currently, using the Sichuan Fire Water Cannon is an ideal fire prevention and extinguishing product, but various common problems may arise during the debugging of the water cannon. What should we do in this situation of worrying about gains and losses?
01
01
有火源出現,水炮卻沒(méi)有反應時(shí),應及時(shí)查看有沒(méi)有拆除火災探測器(紅外,紫外)的保護罩。
When a fire source appears but the water cannon does not respond, it is necessary to promptly check if the protective cover of the fire detector (infrared, ultraviolet) has been removed.
02
02
水炮能發(fā)現火源,卻對不準位置射水時(shí),應分別對水炮的安裝高度、垂直方向、水平方向、定點(diǎn)時(shí)間等進(jìn)行系統參數調節
When the water cannon can detect the source of fire but shoots water from an inaccurate position, the system parameters such as the installation height, vertical direction, horizontal direction, and fixed point time of the water cannon should be adjusted separately
03
03
沒(méi)有火源出現,水炮卻在自行啟動(dòng)時(shí),要查看現場(chǎng)周?chē)欠裼屑t紫外干擾源,應對系統的紅紫外靈敏度進(jìn)行設置。
When there is no fire source present but the water cannon is starting on its own, it is necessary to check if there are any red and ultraviolet interference sources around the scene and set the red and ultraviolet sensitivity of the system.
川消
04
04
水炮控制器開(kāi)機后,卻發(fā)現“主電輸出”燈不亮時(shí),應檢查機器內為水炮供電的空氣開(kāi)關(guān)是否為開(kāi)啟狀態(tài),檢查鏈接空氣開(kāi)關(guān)的連接線(xiàn)是否有斷開(kāi)。
When the water cannon controller is turned on but the "main power output" light is not on, it is necessary to check whether the air switch supplying power to the water cannon in the machine is in an open state and whether the connecting wire to the air switch is disconnected.
05
05
水炮控制的液晶不顯示時(shí),應檢查液晶與顯示板是否連接完好,檢查背光插頭是否插好。
When the LCD controlled by the water cannon does not display, it should be checked whether the LCD is properly connected to the display board and whether the backlight plug is plugged in properly.
06
06
水炮控制的鍵盤(pán)失效時(shí),應檢查軟面板插排是否完好,或可以重新查一下。
When the keyboard of the water cannon control fails, it should be checked whether the soft panel plug is intact, or it can be rechecked.
07
07
水炮控制無(wú)音響出現時(shí),應檢查揚聲器插頭是否插好,或可以重新插一下。
When there is no sound in the water cannon control, it is necessary to check whether the speaker plug is properly plugged in, or it can be reinserted.
08
08
水炮控制器回路出現短路時(shí),應檢查回路總線(xiàn),排查是否是短路。
When there is a short circuit in the water cannon controller circuit, the circuit bus should be checked to see if it is a short circuit.
現在的智能化產(chǎn)品的智能程度比較高,如果擔心設備穩定性,那么可以對設備進(jìn)行多方面了解,及時(shí)檢查設備,消防水炮在國內走過(guò)了很長(cháng)的低谷期,現在水炮性能已經(jīng)穩定,出錯概率非常小,反而作用越來(lái)越大。更多相關(guān)事項就來(lái)咨詢(xún)我們http://m.guizhouhuli.net吧!
The current level of intelligence in intelligent products is relatively high. If you are concerned about the stability of the equipment, you can have a comprehensive understanding of the equipment and timely check the equipment. The fire water monitor has gone through a long period of decline in China, and now the performance of the water monitor is stable, with a very small probability of error, but the effect is becoming increasingly significant. Please consult us for more related matters http://m.guizhouhuli.net Come on!
上一篇:集中控制柜在消防系統中扮演著(zhù)重要的角色
下一篇:水霧噴頭主要性能參數以及布置要求

相關(guān)產(chǎn)品 / Related products

RM新时代投资官网
RM新时代手机版 RM新时代赚钱项目 RM新时代新项目-百度知道 RM新时代官方网站|首入球时间 新时代app游戏 rm新世界 RM新时代有限公司 rm新时代足球交易平台 RM新时代新项目-百度知道 rm理财