干粉滅火系統,由干粉供應源通過(guò)輸送管道連接到固定的噴嘴上,通過(guò)噴嘴噴放干粉的滅火系統。下面川消小編為您講解下干粉滅火系統組件設置以及要求事項吧。
The powder extinguishing system is a fire extinguishing system that connects a dry powder supply source to a fixed nozzle through a conveying pipeline, and sprays dry powder through the nozzle. Below, the editor of Chuanxiao will explain to you the component settings and safety requirements of the dry powder fire extinguishing system.
干粉滅火系統組件的設置要求
Requirements for setting up components of dry powder fire extinguishing systems
(一)儲存裝置
(1) Storage device
(1)干粉儲存容器應符合現行標準《壓力容器技術(shù)監察規程》的規定;驅動(dòng)氣體儲瓶及其充裝系數應符合現行標準《氣瓶監察規程》的規定。
(1) Dry powder storage containers should comply with the current national standard "Supervision Regulations on Safety Technology of Pressure Vessels"; The driving gas storage cylinder and its filling coefficient should comply with the current national standard "Gas Cylinder Safety Supervision Regulations".
(2)干粉儲存容器設計壓力可取1.6MPa或2.5MPa壓力級;其干粉滅火劑的裝量系數不應大于0.85;其增壓時(shí)間不應大于30s。
(2) The design pressure of the dry powder storage container can be 1.6 MPa or 2.5 MPa pressure level; The loading coefficient of its dry powder extinguishing agent should not exceed 0.85; The pressurization time should not exceed 30 seconds.
(3)驅動(dòng)氣體應選用惰性氣體,宜選用氮氣;二氧化碳含水率不應大于0.015%(m/m),其他氣體含水率不得大于0.006%(m/m);驅動(dòng)壓力不得大于干粉儲存容器的高工作壓力。
(3) The driving gas should be inert gas, preferably nitrogen; The moisture content of carbon dioxide should not exceed 0.015% (m/m), and the moisture content of other gases should not exceed 0.006% (m/m); The driving pressure shall not exceed the high working pressure of the dry powder storage container.
(4)儲存裝置的環(huán)境溫度應為-20~50℃。
(4) The ambient temperature of the storage device should be -20~50 ℃.
(二)選擇閥和噴頭
(2) Selection valve and nozzle
(1)系統啟動(dòng)時(shí),選擇閥應在輸出容器閥動(dòng)作之前打開(kāi)。
(1) When the system starts, the selector valve should be opened before the output container valve acts.
(2)噴頭的單孔直徑應大于或等于6mm。
(2) The single hole diameter of the nozzle should be greater than or equal to 6mm.
川消
干粉滅火系統使用要求
Safety requirements for the use of dry powder fire extinguishing systems
1.防護區內及入口處應設火災聲光警報器,防護區入口處應設置干粉滅火劑噴放指示門(mén)燈及干粉滅火系統性標志牌。
1. Fire sound and light alarms should be installed inside and at the entrance of the protection zone, and dry powder fire extinguishing agent spraying indicator door lights and permanent signs of the dry powder fire extinguishing system should be installed at the entrance of the protection zone.
2.防護區的走道和出口,必須保證人員能在30s內疏散。
2. The walkways and exits of the protective zone must ensure that personnel can safely evacuate within 30 seconds.
3.防護區的門(mén)應向疏散方向開(kāi)啟,并應自行關(guān)閉的功能。
3. The door of the protective zone should open in the direction of evacuation and have the function of self closing.
4.防護區入口處應裝設自動(dòng)、手動(dòng)轉換開(kāi)關(guān)。轉換開(kāi)關(guān)安裝高度宜使中心位置距地面1.5m。
4. Automatic and manual transfer switches should be installed at the entrance of the protection zone. The installation height of the transfer switch should be such that the center position is 1.5m above the ground.
5.地下防護區和無(wú)窗或設固定窗扇的地上防護區,應設置獨立的機械排風(fēng)裝置,排風(fēng)口應通向室外。
5. Underground protection areas and above ground protection areas without windows or with fixed window sashes should be equipped with independent mechanical exhaust devices, and the exhaust outlets should lead to the outdoors.
6.局部應用滅火系統,應設置火災聲光警報器。
6. Local fire extinguishing systems should be equipped with sound and light fire alarms.
7.當系統管道設置在有炸危險的場(chǎng)所時(shí),管網(wǎng)等金屬件應設防靜電接地,防靜電接地設計應符合現行有關(guān)標準規定。
When the system pipeline is installed in a place with explosion risk, metal parts such as the pipeline network should be equipped with anti-static grounding, and the anti-static grounding design should comply with the current national standards and regulations.
干粉滅火系統組件設置以及要求就講解到這里了,您對此有怎樣的疑惑或者需求,就來(lái)我們網(wǎng)站http://m.guizhouhuli.net了解吧!
That's all for the component settings and safety requirements of the dry powder fire extinguishing system. If you have any doubts or needs about this, please come to our website http://m.guizhouhuli.net Understand!
上一篇:泡沫消火栓的使用特征以及安裝要求
下一篇:移動(dòng)式高壓細水霧的操作與使用方法

相關(guān)產(chǎn)品 / Related products

RM新时代投资官网
RM新时代手机版 RM新时代赚钱项目 RM新时代新项目-百度知道 RM新时代官方网站|首入球时间 新时代app游戏 rm新世界 RM新时代有限公司 rm新时代足球交易平台 RM新时代新项目-百度知道 rm理财